Know where every unit of energy goes. Then waste less of it.
Ionvik reads your meters and machines live, warns before demand peaks, plans solar and battery use, finds waste with AI, and turns it all into carbon and ESG reports.
Demand at 1,742 kVA, 87% of the 2,000 kVA contract. All loads normal.
Demand at 1,742 kVA, 87% of the 2,000 kVA contract. All loads normal.
See the load. Beat the peak.
Live readings by building, line and machine, and alerts before demand crosses the contracted limit, each with a suggested action your shift engineer can apply in one tap.
- Main incomer1722
- Press shop654
- Paint shop390
- Utilities529
- Compressors212
- Chillers248
- Admin and lighting95
- Unmetered160
| Machine | kW | PF | Current | State |
|---|---|---|---|---|
| Press line A | 212 | 0.96 | 320 A | Running |
| Paint oven | 160 | 0.99 | 225 A | Running |
| Chiller 1 | 125 | 0.93 | 196 A | Running |
| Compressor 1 | 77 | 0.91 | 124 A | Loaded |
| Compressor 3 | 0 | - | - | Standby |
Cheapest power first. Waste out.
Plan when to run on solar, battery or grid. Let the AI find idle machines, compressed-air leaks, night-time loads and poor scheduling, each with an estimated monthly saving.
Every kind of waste leaves the same shape in the data.
Savings Finder knows these six signatures and checks every metered load for them, every day. Amber marks the window that gives it away.
Signal Compressors keep cycling while every air-using machine is stopped.
Signal Load after closing stays above 40% of the daytime level.
Signal Standby draw for long gaps between production counts.
Signal Full load reached long before the first shift clocks in.
Signal Two chillers at low part-load together, or heating and cooling at once.
Signal PF drops at shift change when a capacitor stage fails to switch in.
From meter to carbon ledger to the board pack.
Emissions from electricity, fuel and diesel generators, tracked monthly with the factor behind every line, and reports ready for clients, lenders and boards.
| Source | Scope | Activity | Factor | tCO2e |
|---|---|---|---|---|
Grid electricity National grid, location based | 2 | 418,400 kWh | 0.716 kg/kWh | 299.57 |
Rooftop solar On-site generation | 2 | 61,200 kWh | 0 | 0.00 |
Diesel, DG sets IPCC default | 1 | 2,150 L | 2.68 kg/L | 5.76 |
LPG, paint oven IPCC default | 1 | 1,480 kg | 2.98 kg/kg | 4.41 |
Diesel, forklifts IPCC default | 1 | 820 L | 2.68 kg/L | 2.20 |
| Total, September LOCKED | 311.94 | |||
Twelve sites. One fair yardstick.
Plants, buildings and campuses compared on energy per unit produced, per square foot or per occupied room, adjusted for weather so the ranking is about efficiency, not climate.
Different sites, measured by what they actually do.
Compressors, furnaces, presses, paint ovens, chillers
HVAC, lighting, server rooms, after-hours base load
Chillers, AHUs, sterilisation, imaging, DG backup
HVAC, hot water, laundry, kitchens, pools
Hostels, labs, pumping, street lighting, solar
Thirty days from first reading to a locked baseline.
No rip and replace. Ionvik starts on the meters and systems you run today, and an Ionvik energy engineer stays with you through the first month.
- Day 11Connect
Gateway on the meter network or a link to your BMS. Upload the last 12 bills.
- Day 32Reconcile
Sub-meters are checked against the main incomer and the bill until the totals agree.
- Day 143First findings
Peak alerts are live and the first waste findings arrive with estimated savings.
- Day 304Baseline locked
Carbon Ledger closes its first month and every saving from here is measured.
Four things that never change, whatever plan you are on.
Energy data belongs to the customer. It is encrypted in transit and at rest and never sold.
Automatic control works only if you enable it, on loads you choose, within limits you approve.
Savings before a fix are labelled as estimates. After the fix, the measured saving is reported beside them.
ESG reports are prepared from your data for your review. Final reporting remains your responsibility.
What plant heads and CFOs ask first.
Something else on your mind? Contact us and an energy engineer will reply.
Usually not. We work with existing smart meters, multifunction meters, PLC tags and BMS points, and suggest add-on meters only where a gap is costing you money.
Yes. Upload PDF bills and Ionvik extracts units, maximum demand, power factor, time-of-day consumption and every charge, then reconciles them with meter data.
Peak alerts work from the first week. Waste findings usually appear within two weeks of data. The free savings report estimates what is recoverable from one month of bills and meter data.
The energy and emissions sections are structured to map to the GHG Protocol, GRI 302 and 305, BRSR Principle 6 and the CDP Climate questionnaire.
Data is encrypted in transit and at rest, access is role based per site, and every export is logged. Your data is never sold or shared for advertising.
Only if you enable it, with limits you set: which loads, by how much, for how long and during which hours. It is off by default and every action is logged.